75% of all cobas c analyzer applications need less than 5μl sample material. For all short samples/aliquots the combination of micro sample cups, active level detection and volume optimized applications supports the use of paediatric sample material. Whole blood HbA1c capabilities cobas c enables HbA1c in random access without manualFile Size: 1MB. The cobas c performs a UV test to detect glucose in blood serum and plasma. The enzyme hexokinase (HK) catalyzes the reaction between glucose and adenosine triphosphate (ATP) to form glucosephosphate (GP) and adenosine diphosphate . Read Book Cobas C Analyzer Operator Manual worldwide. It is estimated that 9 million by not using tobacco, having a healthy people will die from cancer worldwide in diet, being physically active, preventing and 4 million will die in infections that.
Only Roche Service representatives may install, service, and repair the system. Roche Diagnostics cobas c analyzer · Software version · Safety Manual · Version 14 Warning messages. The cobas c analyzer is a stand alone system that offers consolidated testing from a broad menu of clinical chemistry applications. This analyzer has the capacity for ion-selective electrode (ISE) determination of sodium, potassium, and chloride in serum, plasma, and urine. In addition, measurement of HbA1c levels in whole blood can also be. This manual describes the cobas c features and general operational concepts, and it provides operating, maintenance, and emergency procedures. How to use this manual To help you find information quickly, there is a table of contents at the beginning of the manual and each chapter. In addition, a complete index can be found at the end.
cobas c. Operator’s Manual. u • Intended use (6) • Symbols and abbreviations (6) Intended use. The. cobas c. analyzer is an automated, softwarecontrolled system for clinical chemistry analysis. It is designed for both quantitative and qualitative in vitro determinations using a large variety of tests for analysis. The. cobas c. The cobas c performs a UV test to detect glucose in blood serum and plasma. The enzyme hexokinase (HK) catalyzes the reaction between glucose and adenosine triphosphate (ATP) to form glucosephosphate (GP) and adenosine diphosphate (ADP). In the presence of nicotinamide adenine. 75% of all cobas c analyzer applications need less than 5μl sample material. For all short samples/aliquots the combination of micro sample cups, active level detection and volume optimized applications supports the use of paediatric sample material. Whole blood HbA1c capabilities cobas c enables HbA1c in random access without manual.
0コメント