Fluke 525b manual






















Your Fluke B Temperature/Pressure Calibrator (referred to as the Calibrator) is an instrument designed to meet the demands of your process tools calibration workload. In addition to the functions in Table , the Calibrator has the following features and functions. • Two line backlit LCD display • . The B is the most accurate Fluke Calibration temperature calibrator, sourcing and measuring a complete range of RTDs, thermocouples, and thermistors. It also measures pressure covering common ranges from 1 inch ( Pa) of water up to 10, PSI (69 Mpa) using the Fluke Calibration Series pressure modules. Your Fluke B Temperature/Pressure Calibrator (referred to as the Calibrator) is an instrument designed to meet the demands of your process tools calibration workload. In addition to the functions in Table 1, the Calibrator has the following features and.


Compact and economical, the A has an interface for automated calibration, providing wide workload coverage in instrument shops and calibration labs, as well as in ATE applications. The B is the most accurate Fluke Calibration temperature calibrator, sourcing and measuring a complete range of RTDs, thermocouples, and thermistors. B Getting Started Manual Supplement 4/10 5 Pressure Measurement The Calibrator can accept either the Fluke or A-P series pressure modules. Pressure modules plug directly into the front panel Lemo connector with the Calibrator firmware autodetecting the type and value of the module you are attaching. The B is the most accurate Fluke Calibration temperature calibrator, sourcing and measuring a complete range of RTDs, thermocouples, and thermistors. It also measures pressure covering common ranges from 1 inch ( Pa) of water up to 10, PSI (69 Mpa) using the Fluke Calibration Series or A-P pressure modules.


B Users Manual Supplement 8/09 1 Change #1 Replace page with the following: Testing DC Current Output Use the A and the precision shunt to measure the B output as shown in Figure Take the Voltage reading from the A and divide it by the A-1 actual value to determine the current output. B Users Manual Measuring Pressure Many ranges and types of pressure modules are available from Fluke. See “Accessories” in Chapter 6 of this manual for a complete list of supported pressure modules. B Getting Started Manual Supplement 4/10 5 Pressure Measurement The Calibrator can accept either the Fluke or A-P series pressure modules. Pressure modules plug directly into the front panel Lemo connector with the Calibrator firmware autodetecting the type and value of the module you are attaching.

0コメント

  • 1000 / 1000